WDM 8000
Wireless data modem 9600/19200 Baud with RS232 interface
With the wireless data modem WDM 8000, you can easily monitor and control windmills, solar parks and biogas plants. It transfers serial data (RS232) using standard radio channels with the frequency bands 8m*, 4m, 2m and 70cm. The data modem is designed for the use in industries like electricity, water, energy and the transportation industries.Use a 25-pole D-Sub connector to connect the WDM 8000 with a power supply (8 to 16 or 18 to 60 Volts DC) and external devices. The interface has 4 additional digital or analog* in and outputs.
With the accessories set (cable and software), you can easily adjust important parameters like R232-settings, transmission and reception frequency and the transmission power output.
The numerous function- and status indicators at the front of the data modem indicate the current status of the device. Over the 25-pole interface, data can be read and processed.
Because of the robust metal housing (IP54), you can install the data modem on a DIN rail or directly onto a flat surface. You can get the data modem with the signal modulation FFSK (9600 Bd/ 19200 Bd).
*on request
Technical data
Operating voltage | 8 to 16 V DC DC or 18 to 60 V DC |
Power consumption | Max. 2.0 A (at 5 Watt transmission power), 70 mA (Standby) |
Temperature range | -25°C … +55°C |
Antenna connection | SMA, 50 Ohm, male |
Dimensions (HxWxD) | 179 x 69 x 37 mm |
Weight | 428g |
Installation type | wall / DIN rail |
Frequency domains | 68 – 87,5 MHz / 136 – 174 MHz 335 – 405 MHz / 400 – 470 MHz (others on request) |
Channel spacing | 12,5 / 25 KHz |
Number of channels | 127 |
Modulation | FFSK / GMSK |
Mode | Simplex / Semi-Duplex (adjustable) |
Transmission power | 0,5 -1-3-5 W / 50 Ohm (adjustable) |
Transmit/receive changeover | Simplex < 15 ms / Semi-Duplex < 2 ms |
Sensivity (receiver) | -107 dBm 19.200 vers. 4level FSK (BER < 10 E-4) |
Adjacent-channel selectivity | > 60 dB at 12,5 kHz > 70 dB at 25 kHz |
Interface | RS232 |
Connection | D-Sub 25 pole, male |
Data rate (wire) | 300 – 115.200 bps |
Data rate (radio) | 19.200 bps (25 kHz) / 9600 (12,5 kHz) |
Data formats | asynchronous |
Data protocol | transparent (others on request) |
European Norms | ETS 300 086; ETS 300 113, ETS 300 279 |
EU Directive | 2014/53/EU |